Oil & gas

SAF® for produced water and frac water

Suspended Air®/Gas flotation helps operators reuse frac water or prepare it for deep-well disposal, and supports produced-water recovery and recycling in oil sands extraction.

Frac water reuse or disposalProduced water recyclingCan float with methane instead of air

At a glance

SAF® for oil & gas water

TargetsOil/water separation and suspended solids in frac and produced water
GoalsCompliance with water quality standards for frac water reuse or deep-well disposal; produced-water recovery and recycling
Gas optionSAF® can use methane instead of air, eliminating oxygen from the process, similar to induced gas flotation (IGF)
MechanicsFroth is not made by impellers, eductors or spargers; no parallel-plate packing is needed
Not limited byGas solubility, pressure or temperature
SizingClearFloater™ CF25 to CF3000; recommended flows from 10 to 8,000 gpm

How it works

How SAF® treats frac and produced water

Tap each stage of the treatment train.

→→→→→→

Influent

Frac flowback or produced water is fed to the SAF® system.

Why SAF®

Why operators consider SAF®

Oxygen-free option

Run on methane instead of air to keep oxygen out of the process.

No packing to foul

High efficiency without parallel-plate packing.

No spargers or eductors

Froth is generated externally, not by impellers, eductors or spargers.

Reuse-ready

Treated water supports frac water reuse and produced-water recycling.

Engineer's notes

What engineers ask us about oil & gas

What comes in a standard SAF® system?
An influent flow meter, coagulant metering pump, polymer activation and aging system, Suspended Air® Emulsion (SAF®) Generator, ClearFloater™ flotation separator and process control panel. pH control with acid/base metering can be added. Systems can be supplied as components or as fully integrated, skid- or trailer-mounted units, typically fabricated from 304 stainless steel.
How is the SAF® froth made, and how much air does it carry?
The SAF® generator makes the froth outside the process stream from a surfactant blend, water and air. In the Simmons Foods data, one gallon of froth is about 0.8 mL of surfactant, 0.6 gal of water and 0.4 gal of air, so roughly 40% air by volume. The 7–25 µm aphrons resist coalescing, and no air is dissolved under pressure, so performance is not tied to gas solubility, pressure or water temperature.
What chemistry does SAF® use?
Coagulant and polymer are dosed to build floc, typically through a pipeline flocculation reactor, and the froth and polymer are mixed into the influent in the ClearMixer™ before the flotation cell. Jar tests set the doses for your water. In the conversions we have published, polymer use fell: 50% less at Fieldale Farms, and 120 to 60 lb/day at Simmons Foods.
How is SAF® sized?
By hydraulic loading (gpm per ft² of float area) and solids loading (lb/hr per ft²). Simmons Foods units float 20–40 lb/hr/ft² of solids, specified at 30. ClearFloater™ models run from CF25 to CF3000, with recommended flows from 10 to 8,000 gpm. Try the ClearFloater™ sizer →
Can we convert an existing DAF instead?
Yes. A conversion adds a SAF® generator and a ClearMixer™ to the existing tank. Fieldale Farms converted two DAFs over consecutive weekends and went from 900 to 1,500 gpm per tank. Simmons Foods raised a primary DAF from a 1,250 gpm maximum to 2,400 gpm in the same float cell. See conversions →
What does it cost, and what does it cost to run?
Initial cost is in line with traditional and competing technologies. SAF® needs less footprint, connected horsepower and chemistry, which lowers construction, installation and operating cost. At Simmons Foods, converting the secondary DAF cut yearly O&M from $468,967 to $227,810. Run the energy calculator →
How hard is it to start up and operate?
Start-up is a matter of hours, not days. Operators describe SAF® as simple to run and easy to keep in compliance. Heron provides on-site start-up training, a full O&M manual and periodic site visits with a complimentary follow-up report, and the SAF® generator module carries a lifetime guarantee.

See the difference

SAF® vs. conventional DAF

Animation is illustrative, not to scale.

  • Bubbles7–25 µm aphrons: double-walled, surfactant-coated and electrically charged
  • How they formGenerated outside the tank as a microbubble suspension, then blended into the flow
  • Limited byNot limited by gas solubility, pressure or temperature
  • Solids loadingUp to about 10× a conventional DAF thickener on equal area (Nashville pilot)
  • RetrofitExisting DAF tanks can be converted to SAF® service

SAF®/SGF™

Flotation technology offers wastewater treatment solutions for hydraulic fracturing operations. Our innovative solutions ensure that facilities can achieve compliance with water quality standards, allowing for the reuse of frack water or its safe disposal into deep wells.

Water plays a pivotal role in oil sands extraction, and the utilization of efficient water treatment technologies, such as Suspended Air®/Gas® flotation, is essential for enhancing the recovery and recycling of produced water to support further operational processes.

Request A Free Consultation

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Name*

Next step

What we need to size your system

  • Design flow (gpm or MGD), average and peak
  • Influent TSS, FOG, BOD and COD, with variability
  • Current treatment train, and any DAF you could convert
  • Discharge, permit or reuse limits
  • Oil-in-water, TSS and salinity
  • Reuse vs. disposal targets
  • Available space and site constraints
  • Timeline and budget

Jar tests

We bench-test your water and project performance, polymer and coagulant dosing, and operating cost.

Pilot on site

Lease a trailer-mounted SAF® pilot with pH control, polymer dosing and aging, and a flotation tank.

Design, start-up and support

New or retrofit design, on-site start-up training, a full O&M manual and periodic site visits.

Put SAF® to the test

Have a flotation problem? Let's run it on your water.

Send us your flow, solids and goals. Our engineers will size a Suspended Air® Flotation (SAF®) system, or set up a pilot on site so you can see the results first.